Slc4a10 Mouse siRNA Oligo Duplex (Locus ID 94229)
CAT#: SR422016
Slc4a10 (Mouse) - 3 unique 27mer siRNA duplexes - 2 nmol each
Need single siRNA in bulk?
Get a free quote
CNY 4,090.00
货期*
7周
规格
Product images
经常一起买 (2)
Specifications
Product Data | |
Purity | HPLC purified |
Quality Control | Tested by ESI-MS |
Sequences | Available with shipment |
Stability | One year from date of shipment when stored at -20°C. |
# of transfections | Approximately 330 transfections/2nmol in 24-well plate under optimized conditions (final conc. 10 nM). |
Note | Single siRNA duplex (10nmol) can be ordered. |
Reference Data | |
RefSeq | NM_001242378, NM_001242379, NM_001242380, NM_001242381, NM_001242382, NM_001242383, NM_033552, NM_001362671, NM_001362672, NM_001362673, NM_001362674, NM_001362675, NM_001362676 |
Synonyms | mKIAA4136; NCBE |
Components | Slc4a10 (Mouse) - 3 unique 27mer siRNA duplexes - 2 nmol each (Locus ID 94229)Included - SR30004, Trilencer-27 Universal Scrambled Negative Control siRNA Duplex - 2 nmolIncluded - SR30005, RNAse free siRNA Duplex Resuspension Buffer - 2 ml |
Summary | Sodium/bicarbonate cotransporter which plays an important role in regulating intracellular pH (PubMed:10993873, PubMed:20566632). Has been shown to act as a sodium/bicarbonate cotransporter in exchange for intracellular chloride (PubMed:10993873, PubMed:20566632). Has also been shown to act as a sodium/biocarbonate cotransporter which is not responsible for net efflux of chloride, with the observed chloride efflux being due to chloride self-exchange (By similarity). Controls neuronal pH and may contribute to the secretion of cerebrospinal fluid (PubMed:18165320). Reduces the excitability of CA1 pyramidal neurons and modulates short-term synaptic plasticity (PubMed:26136660). Required in retinal cells to maintain normal pH which is necessary for normal vision (PubMed:23056253). In the kidney, likely to mediate bicarbonate reclamation in the apical membrane of the proximal tubules (By similarity).[UniProtKB/Swiss-Prot Function] |
Performance Guranteed | OriGene guarantees that at least two of the three Dicer-Substrate duplexes in the kit will provide at least 70% or more knockdown of the target mRNA when used at 10 nM concentration by quantitative RT-PCR when the TYE-563 fluorescent transfection control duplex (cat# SR30002) indicates that >90% of the cells have been transfected and the HPRT positive control (cat# SR30003) provides 90% knockdown efficiency. For non-conforming siRNA, requests for replacement product must be made within ninety (90) days from the date of delivery of the siRNA kit. To arrange for a free replacement with newly designed duplexes, please contact Technical Services at techsupport@origene.com. Please provide your data indicating the transfection efficiency and measurement of gene expression knockdown compared to the scrambled siRNA control (quantitative RT-PCR data required). |
Documents
Product Manuals |
FAQs |
SDS |
其它Slc4a10产品
Customer
Reviews
Loading...