Dr1 Mouse shRNA Plasmid (Locus ID 13486)

CAT#: TL509622

Dr1 - Mouse, 4 unique 29mer shRNA constructs in lentiviral GFP vector, 5µg of each construct provided



Need custom shRNA service?
Get a free quote

参与“shRNA产品第二件享半价”限时优惠活动

CNY 7,740.00


货期*
2周

规格
    • 1 kit

Product images

经常一起买 (4)
Lenti-vpak packaging kit - packaging plasmids and transfection reagent
    • 10 reactions

CNY 5,420.00


TurboFectin Transfection Reagent (1 mL in 1 vial)
    • 1 ml in 1 vial

CNY 4,090.00


Dr1 Antibody - middle region
    • 50 ug

CNY 4,628.00


Lateral flow testing sticks used for the semi-quantitative detection of the lentiviral p24 protein, 20 tests
    • 20 Tests

CNY 4,070.00

Specifications

Product Data
Product Name Dr1 Mouse shRNA Plasmid (Locus ID 13486)
Locus ID 13486
UniProt ID Q91WV0
Synonyms 1700121L09Rik; Dr1l; NC2; NC2beta
Vector pGFP-C-shLenti
Format Lentiviral plasmids
Kit Components Dr1 - Mouse, 4 unique 29mer shRNA constructs in lentiviral GFP vector(Gene ID = 13486). 5µg purified plasmid DNA per construct
29-mer scrambled shRNA cassette in pGFP-C-shLenti Vector, TR30021, included for free.
RefSeq BC013461, NM_026106, NM_026106.1, NM_026106.2, NM_026106.3, NM_026106.4
Summary The association of the DR1/DRAP1 heterodimer with TBP results in a functional repression of both activated and basal transcription of class II genes. This interaction precludes the formation of a transcription-competent complex by inhibiting the association of TFIIA and/or TFIIB with TBP. Can bind to DNA on its own. Component of the ATAC complex, a complex with histone acetyltransferase activity on histones H3 and H4 (By similarity).[UniProtKB/Swiss-Prot Function]
shRNA Design These shRNA constructs were designed against multiple splice variants at this gene locus. To be certain that your variant of interest is targeted, please contact techsupport@origene.com. If you need a special design or shRNA sequence, please utilize our custom shRNA service.
Performance Guaranteed OriGene guarantees that the sequences in the shRNA expression cassettes are verified to correspond to the target gene with 100% identity. One of the four constructs at minimum are guaranteed to produce 70% or more gene expression knock-down provided a minimum transfection efficiency of 80% is achieved. Western Blot data is recommended over qPCR to evaluate the silencing effect of the shRNA constructs 72 hrs post transfection. To properly assess knockdown, the gene expression level from the included scramble control vector must be used in comparison with the target-specific shRNA transfected samples.

For non-conforming shRNA, requests for replacement product must be made within ninety (90) days from the date of delivery of the shRNA kit. To arrange for a free replacement with newly designed constructs, please contact Technical Services at techsupport@origene.com. Please provide your data indicating the transfection efficiency and measurement of gene expression knockdown compared to the scrambled shRNA control (Western Blot data preferred).
*Delivery time may vary from web posted schedule. Occasional delays may occur due to unforeseen complexities in the preparation of your product. International customers may expect an additional 1-2 weeks in shipping.
Customer Reviews 
Loading...