Kv4.3 (KCND3) Human siRNA Oligo Duplex (Locus ID 3752)

CAT#: SR302521

KCND3 (Human) - 3 unique 27mer siRNA duplexes - 2 nmol each



Need single siRNA in bulk?
Get a free quote

CNY 4,090.00


货期*
4周

规格
    • 1 kit

Product images

经常一起买 (3)
siTran 2.0 siRNA transfection reagent (0.5ml)
    • 500 ul

CNY 2,190.00


Trilencer-27 Fluorescent-labeled transfection control siRNA duplex - 1 nmol
    • 1 nmol

CNY 1,090.00


KCND3 Rabbit polyclonal Antibody
    • 100 ul

CNY 1,999.00
CNY 3,280.00

热销推荐

Specifications

Product Data
Purity HPLC purified
Quality Control Tested by ESI-MS
Sequences Available with shipment
Stability One year from date of shipment when stored at -20°C.
# of transfections Approximately 330 transfections/2nmol in 24-well plate under optimized conditions (final conc. 10 nM).
Note Single siRNA duplex (10nmol) can be ordered.
Reference Data
RefSeq NM_004980, NM_172198
Synonyms BRGDA9; KCND3L; KCND3S; KSHIVB; KV4.3; SCA19; SCA22
Components KCND3 (Human) - 3 unique 27mer siRNA duplexes - 2 nmol each (Locus ID 3752)
Included - SR30004, Trilencer-27 Universal Scrambled Negative Control siRNA Duplex - 2 nmol
Included - SR30005, RNAse free siRNA Duplex Resuspension Buffer - 2 ml
Summary Voltage-gated potassium (Kv) channels represent the most complex class of voltage-gated ion channels from both functional and structural standpoints. Their diverse functions include regulating neurotransmitter release, heart rate, insulin secretion, neuronal excitability, epithelial electrolyte transport, smooth muscle contraction, and cell volume. Four sequence-related potassium channel genes - shaker, shaw, shab, and shal - have been identified in Drosophila, and each has been shown to have human homolog(s). This gene encodes a member of the potassium channel, voltage-gated, shal-related subfamily, members of which form voltage-activated A-type potassium ion channels and are prominent in the repolarization phase of the action potential. This member includes two isoforms with different sizes, which are encoded by alternatively spliced transcript variants of this gene. [provided by RefSeq, Jul 2008]
Performance Guranteed OriGene guarantees that at least two of the three Dicer-Substrate duplexes in the kit will provide at least 70% or more knockdown of the target mRNA when used at 10 nM concentration by quantitative RT-PCR when the TYE-563 fluorescent transfection control duplex (cat# SR30002) indicates that >90% of the cells have been transfected and the HPRT positive control (cat# SR30003) provides 90% knockdown efficiency.

For non-conforming siRNA, requests for replacement product must be made within ninety (90) days from the date of delivery of the siRNA kit. To arrange for a free replacement with newly designed duplexes, please contact Technical Services at techsupport@origene.com. Please provide your data indicating the transfection efficiency and measurement of gene expression knockdown compared to the scrambled siRNA control (quantitative RT-PCR data required).
*Delivery time may vary from web posted schedule. Occasional delays may occur due to unforeseen complexities in the preparation of your product. International customers may expect an additional 1-2 weeks in shipping.

Documents

Customer Reviews 
Loading...