ADA2a (TADA2A) Human siRNA Oligo Duplex (Locus ID 6871)
CAT#: SR304692
TADA2A (Human) - 3 unique 27mer siRNA duplexes - 2 nmol each
Need single siRNA in bulk?
Get a free quote
CNY 4,090.00
货期*
7周
规格
Product images
经常一起买 (3)
Specifications
Product Data | |
Purity | HPLC purified |
Quality Control | Tested by ESI-MS |
Sequences | Available with shipment |
Stability | One year from date of shipment when stored at -20°C. |
# of transfections | Approximately 330 transfections/2nmol in 24-well plate under optimized conditions (final conc. 10 nM). |
Note | Single siRNA duplex (10nmol) can be ordered. |
Reference Data | |
RefSeq | NM_001166105, NM_001291918, NM_001488, NM_133439 |
Synonyms | ADA2; ADA2A; hADA2; KL04P; TADA2L |
Components | TADA2A (Human) - 3 unique 27mer siRNA duplexes - 2 nmol each (Locus ID 6871)Included - SR30004, Trilencer-27 Universal Scrambled Negative Control siRNA Duplex - 2 nmolIncluded - SR30005, RNAse free siRNA Duplex Resuspension Buffer - 2 ml |
Summary | Many DNA-binding transcriptional activator proteins enhance the initiation rate of RNA polymerase II-mediated gene transcription by interacting functionally with the general transcription machinery bound at the basal promoter. Adaptor proteins are usually required for this activation, possibly to acetylate and destabilize nucleosomes, thereby relieving chromatin constraints at the promoter. The protein encoded by this gene is a transcriptional activator adaptor and has been found to be part of the PCAF histone acetylase complex. Several alternatively spliced transcript variants encoding different isoforms of this gene have been described, but the full-length nature of some of these variants has not been determined. [provided by RefSeq, Oct 2009] |
Performance Guranteed | OriGene guarantees that at least two of the three Dicer-Substrate duplexes in the kit will provide at least 70% or more knockdown of the target mRNA when used at 10 nM concentration by quantitative RT-PCR when the TYE-563 fluorescent transfection control duplex (cat# SR30002) indicates that >90% of the cells have been transfected and the HPRT positive control (cat# SR30003) provides 90% knockdown efficiency. For non-conforming siRNA, requests for replacement product must be made within ninety (90) days from the date of delivery of the siRNA kit. To arrange for a free replacement with newly designed duplexes, please contact Technical Services at techsupport@origene.com. Please provide your data indicating the transfection efficiency and measurement of gene expression knockdown compared to the scrambled siRNA control (quantitative RT-PCR data required). |
Documents
Product Manuals |
FAQs |
SDS |
Customer
Reviews