CAMTA1 Human siRNA Oligo Duplex (Locus ID 23261)
CAT#: SR308138
CAMTA1 (Human) - 3 unique 27mer siRNA duplexes - 2 nmol each
Need single siRNA in bulk?
Get a free quote
CNY 4,090.00
货期*
4周
规格
Product images
经常一起买 (3)
Specifications
Product Data | |
Purity | HPLC purified |
Quality Control | Tested by ESI-MS |
Sequences | Available with shipment |
Stability | One year from date of shipment when stored at -20°C. |
# of transfections | Approximately 330 transfections/2nmol in 24-well plate under optimized conditions (final conc. 10 nM). |
Note | Single siRNA duplex (10nmol) can be ordered. |
Reference Data | |
RefSeq | NM_001195563, NM_001242701, NM_015215, NR_038934, NM_001349608, NM_001349609, NM_001349610, NM_001349612, NM_001349613, NM_001349614, NM_001349615, NM_001349616, NM_001349617, NM_001349618, NM_001349619, NM_001349620, NM_001349621, NM_001349622, NM_001349623, NM_001349624, NM_001349625, NM_001349626, NM_001349627, NR_146202, NR_146203, NR_146204 |
Synonyms | CANPMR |
Components | CAMTA1 (Human) - 3 unique 27mer siRNA duplexes - 2 nmol each (Locus ID 23261)Included - SR30004, Trilencer-27 Universal Scrambled Negative Control siRNA Duplex - 2 nmolIncluded - SR30005, RNAse free siRNA Duplex Resuspension Buffer - 2 ml |
Summary | The protein encoded by this gene contains a CG1 DNA-binding domain, a transcription factor immunoglobulin domain, ankyrin repeats, and calmodulin-binding IQ motifs. The encoded protein is thought to be a transcription factor and may be a tumor suppressor. However, a translocation event is sometimes observed between this gene and the WWTR1 gene, with the resulting WWTR1-CAMTA1 oncoprotein leading to epithelioid hemangioendothelioma, a malignant vascular cancer. [provided by RefSeq, Mar 2017] |
Performance Guranteed | OriGene guarantees that at least two of the three Dicer-Substrate duplexes in the kit will provide at least 70% or more knockdown of the target mRNA when used at 10 nM concentration by quantitative RT-PCR when the TYE-563 fluorescent transfection control duplex (cat# SR30002) indicates that >90% of the cells have been transfected and the HPRT positive control (cat# SR30003) provides 90% knockdown efficiency. For non-conforming siRNA, requests for replacement product must be made within ninety (90) days from the date of delivery of the siRNA kit. To arrange for a free replacement with newly designed duplexes, please contact Technical Services at techsupport@origene.com. Please provide your data indicating the transfection efficiency and measurement of gene expression knockdown compared to the scrambled siRNA control (quantitative RT-PCR data required). |
Documents
Product Manuals |
FAQs |