GGCX Human siRNA Oligo Duplex (Locus ID 2677)
CAT#: SR320282
GGCX (Human) - 3 unique 27mer siRNA duplexes - 2 nmol each
Need single siRNA in bulk?
Get a free quote
SR320282 is the updated version of SR301787.
CNY 4,090.00
货期*
7周
规格
Product images
经常一起买 (3)
Specifications
Product Data | |
Purity | HPLC purified |
Quality Control | Tested by ESI-MS |
Sequences | Available with shipment |
Stability | One year from date of shipment when stored at -20°C. |
# of transfections | Approximately 330 transfections/2nmol in 24-well plate under optimized conditions (final conc. 10 nM). |
Note | Single siRNA duplex (10nmol) can be ordered. |
Reference Data | |
RefSeq | NM_000821, NM_001142269, NM_001311312 |
Synonyms | VKCFD1 |
Components | GGCX (Human) - 3 unique 27mer siRNA duplexes - 2 nmol each (Locus ID 2677)Included - SR30004, Trilencer-27 Universal Scrambled Negative Control siRNA Duplex - 2 nmolIncluded - SR30005, RNAse free siRNA Duplex Resuspension Buffer - 2 ml |
Summary | This gene encodes an integral membrane protein of the rough endoplasmic reticulum that carboxylates glutamate residues of vitamin K-dependent proteins to gamma carboxyl glutamate, a modification that is required for their activity. The vitamin K-dependent protein substrates have a propeptide that binds the enzyme, with carbon dioxide, dioxide, and reduced vitamin K acting as co-substrates. Vitamin K-dependent proteins affect a number of physiologic processes including blood coagulation, prevention of vascular calcification, and inflammation. Allelic variants of this gene have been associated with pseudoxanthoma elasticum-like disorder with associated multiple coagulation factor deficiency. Alternative splicing results in multiple transcript variants. [provided by RefSeq, Aug 2015] |
Performance Guranteed | OriGene guarantees that at least two of the three Dicer-Substrate duplexes in the kit will provide at least 70% or more knockdown of the target mRNA when used at 10 nM concentration by quantitative RT-PCR when the TYE-563 fluorescent transfection control duplex (cat# SR30002) indicates that >90% of the cells have been transfected and the HPRT positive control (cat# SR30003) provides 90% knockdown efficiency. For non-conforming siRNA, requests for replacement product must be made within ninety (90) days from the date of delivery of the siRNA kit. To arrange for a free replacement with newly designed duplexes, please contact Technical Services at techsupport@origene.com. Please provide your data indicating the transfection efficiency and measurement of gene expression knockdown compared to the scrambled siRNA control (quantitative RT-PCR data required). |
Documents
Product Manuals |
FAQs |
SDS |
Customer
Reviews
Loading...