Luciferase Rabbit Polyclonal Antibody

CAT#: AP21341AF-N

Luciferase rabbit polyclonal antibody, Azide Free



Need it in bulk or conjugated?
Get a free quote

CNY 3,402.00


货期*
5周

规格
    • 10 mg

Product images

Specifications

Product Data
Applications ELISA, IF, WB
Recommend Dilution ELISA.
Dot blot.
Immunoblotting.
Indirect Immunofluorescence.

Working Dilutions for Non-precipitating antibody-binding techniques: 1/1000-1/10000.
This product is intended for use in precipitating and non-precipitating antibody-binding assays (such as e.g., ELISA and Western blotting and Immunofluorescence or Histochemical techniques), to prepare an insoluble immuno-affinity adsorbent, for labelling with a marker of choice.
Reactivity Photinus pyralis
Host Rabbit
Clonality Polyclonal
Immunogen Luciferase isolated and purified from Photinus pyralis.
Freund’s complete adjuvant is used in the first step of the immunization procedure.
Specificity IgG fraction of Polyclonal Rabbit antiserum to Luciferase from Photinus pyralis.
The reagents were evaluated for potency, purity and specificity using most or all of the following techniques: Immunoelectrophoresis, Cross-Immunoelectrophoresis, Single Radial Immunodiffusion (Ouchterlony), block titration, ELISA, Immunoblotting and enzyme inhibition.
Cross-reactivities against enzymes of other sources may occur but have not been determined.
Formulation PBS, pH 7.2 without preservatives and foreign proteins
State: Azide Free
State: Lyophilized purified hyperimmune IgG fraction
Reconstitution Method Restore by adding 1.0 ml sterile distilled water.
Concentration lot specific
Conjugation Unconjugated
Storage Condition Store lyophilized at 2-8°C for 6 months or at -20°C long term.
After reconstitution store the antibody undiluted at 2-8°C for one month
or (in aliquots) at -20°C long term.
Avoid repeated freezing and thawing.
Background Luciferase from the firefly has become one of the more widely used reporter proteins for the study of gene expression. Luciferase catalyzes a bioluminescent reaction which requires the substrate luciferin as well as Mg2+ and ATP. Mixing these reagents with the cell extract containing luciferase, results in a flash of light that decays rapidly. This light can be detected by a luminometer. The total light emission is proportional to the luciferase activity of the sample.