Luciferase Rabbit Polyclonal Antibody

CAT#: AP21341BT-N

Luciferase rabbit polyclonal antibody, Biotin

Conjugation: Unconjugated Biotin



Need it in bulk or conjugated?
Get a free quote

CNY 5,640.00


货期*
5周

规格
    • 1 ml

Product images

Specifications

Product Data
Applications ELISA, ID, IF, IP, R, WB
Recommend Dilution This product is intended for use in precipitating and non-precipitating antibody-binding assays such as e.g., ELISA and Western blotting and Immunofluorescence or Histochemical techniques (1/1,000-1/10,000).
Reactivity Photinus pyralis
Host Rabbit
Clonality Polyclonal
Immunogen Luciferase isolated and purified from Photinus pyralis.
Freund’s complete adjuvant is used in the first step of the immunization procedure.
Specificity The reagents were evaluated for potency, purity and specificity using most or all of the following techniques: Immunoelectrophoresis, Cross-Immunoelectrophoresis, single Radial Immunodiffusion (Ouchterlony), block titration, ELISA, Immunoblotting and Enzyme Inhibition.
Cross-reactivities against enzymes of other sources may occur but have not been determined.
Formulation PBS, pH 7.2 without preservatives and foreign proteins.
Label: Biotin
State: Lyophilized purified IgG fraction.
Molar radio: Biotin/IgG: ~1.7
Reconstitution Method Restore by adding 1.0 ml of sterile distilled water.
Concentration lot specific
Purification Ammonium Sulphate Precipitation and Ion Exchange Chromatography.
Conjugation Biotin
Storage Condition Store lyophilized at 2-8°C for 6 months or at -20°C long term.
After reconstitution store the antibody undiluted at 2-8°C for one month
or (in aliquots) at -20°C long term.
If a slight precipitation occurs upon storage, this should be removed by centrifugation.
Avoid repeated freezing and thawing.
Background Luciferase from the firefly has become one of the more widely used reporter proteins for the study of gene expression. Luciferase catalyzes a bioluminescent reaction which requires the substrate luciferin as well as Mg2+ and ATP. Mixing these reagents with the cell extract containing luciferase, results in a flash of light that decays rapidly. This light can be detected by a luminometer. The total light emission is proportional to the luciferase activity of the sample.
Reference Data
*Delivery time may vary from web posted schedule. Occasional delays may occur due to unforeseen complexities in the preparation of your product. International customers may expect an additional 1-2 weeks in shipping.
Customer Reviews 
Loading...