MTCO2 (COX2) Human shRNA Plasmid Kit (Locus ID 4513)

CAT#: TG319077

COX2 - Human, 4 unique 29mer shRNA constructs in retroviral GFP vector, 5µg of each construct provided



Need custom shRNA service?
Get a free quote

参与“shRNA产品第二件享半价”限时优惠活动

CNY 2,731.00


货期*
现货

规格
    • 1 kit

Product images

经常一起买 (2)
TurboFectin Transfection Reagent (1 mL in 1 vial)
    • 1 ml in 1 vial

CNY 4,090.00


MT-CO2 rabbit polyclonal antibody
    • 100 ul

CNY 1,999.00
CNY 3,280.00

Specifications

Product Data
Product Name MTCO2 (COX2) Human shRNA Plasmid Kit (Locus ID 4513)
Locus ID 4513
UniProt ID P00403
Synonyms COII
Vector pGFP-V-RS
Format Retroviral plasmids
Kit Components COX2 - Human, 4 unique 29mer shRNA constructs in retroviral GFP vector(Gene ID = 4513). 5µg purified plasmid DNA per construct
29-mer scrambled shRNA cassette in pGFP-V-RS Vector, TR30013, included for free.
RefSeq NM_173705, NM_173705.1
Summary Cytochrome c oxidase is the component of the respiratory chain that catalyzes the reduction of oxygen to water. Subunits 1-3 form the functional core of the enzyme complex. Subunit 2 transfers the electrons from cytochrome c via its binuclear copper A center to the bimetallic center of the catalytic subunit 1. [UniProtKB/Swiss-Prot Function]
shRNA Design These shRNA constructs were designed against multiple splice variants at this gene locus. To be certain that your variant of interest is targeted, please contact techsupport@origene.com. If you need a special design or shRNA sequence, please utilize our custom shRNA service.
Performance Guaranteed OriGene guarantees that the sequences in the shRNA expression cassettes are verified to correspond to the target gene with 100% identity. One of the four constructs at minimum are guaranteed to produce 70% or more gene expression knock-down provided a minimum transfection efficiency of 80% is achieved. Western Blot data is recommended over qPCR to evaluate the silencing effect of the shRNA constructs 72 hrs post transfection. To properly assess knockdown, the gene expression level from the included scramble control vector must be used in comparison with the target-specific shRNA transfected samples.

For non-conforming shRNA, requests for replacement product must be made within ninety (90) days from the date of delivery of the shRNA kit. To arrange for a free replacement with newly designed constructs, please contact Technical Services at techsupport@origene.com. Please provide your data indicating the transfection efficiency and measurement of gene expression knockdown compared to the scrambled shRNA control (Western Blot data preferred).
*Delivery time may vary from web posted schedule. Occasional delays may occur due to unforeseen complexities in the preparation of your product. International customers may expect an additional 1-2 weeks in shipping.
Customer Reviews 
Loading...