TFIIS (TCEA2) Human shRNA Plasmid Kit (Locus ID 6919)

CAT#: TL308915

TCEA2 - Human, 4 unique 29mer shRNA constructs in lentiviral GFP vector, 5µg of each construct provided



Need custom shRNA service?
Get a free quote

CNY 7,740.00


货期*
2周

规格
    • 1 kit

Product images

经常一起买 (4)
Lenti-vpak packaging kit - packaging plasmids and transfection reagent
    • 10 reactions

CNY 5,420.00


TurboFectin Transfection Reagent (1 mL in 1 vial)
    • 1 ml in 1 vial

CNY 4,090.00


Rabbit Polyclonal Anti-TCEA2 Antibody
    • 100 ug

CNY 4,537.00


Lateral flow testing sticks used for the semi-quantitative detection of the lentiviral p24 protein, 20 tests
    • 20 Tests

CNY 4,070.00

Specifications

Product Data
Product Name TFIIS (TCEA2) Human shRNA Plasmid Kit (Locus ID 6919)
Locus ID 6919
UniProt ID Q15560
Synonyms TFIIS
Vector pGFP-C-shLenti
Format Lentiviral plasmids
Kit Components TCEA2 - Human, 4 unique 29mer shRNA constructs in lentiviral GFP vector(Gene ID = 6919). 5µg purified plasmid DNA per construct
29-mer scrambled shRNA cassette in pGFP-C-shLenti Vector, TR30021, included for free.
RefSeq NM_003195, NM_198723, NM_198723.1, NM_198723.2, NM_003195.1, NM_003195.2, NM_003195.3, NM_003195.4, NM_003195.5, BC018896, BC018896.2, BC014211, BC031877, BC050623, BC050624, BC056407, BC098585, NM_003195.6
Summary The protein encoded by this gene is found in the nucleus, where it functions as an SII class transcription elongation factor. Elongation factors in this class are responsible for releasing RNA polymerase II ternary complexes from transcriptional arrest at template-encoded arresting sites. The encoded protein has been shown to interact with general transcription factor IIB, a basal transcription factor. Two transcript variants encoding different isoforms have been found for this gene. [provided by RefSeq, Jul 2008]
shRNA Design These shRNA constructs were designed against multiple splice variants at this gene locus. To be certain that your variant of interest is targeted, please contact techsupport@origene.com. If you need a special design or shRNA sequence, please utilize our custom shRNA service.
Performance Guaranteed OriGene guarantees that the sequences in the shRNA expression cassettes are verified to correspond to the target gene with 100% identity. One of the four constructs at minimum are guaranteed to produce 70% or more gene expression knock-down provided a minimum transfection efficiency of 80% is achieved. Western Blot data is recommended over qPCR to evaluate the silencing effect of the shRNA constructs 72 hrs post transfection. To properly assess knockdown, the gene expression level from the included scramble control vector must be used in comparison with the target-specific shRNA transfected samples.

For non-conforming shRNA, requests for replacement product must be made within ninety (90) days from the date of delivery of the shRNA kit. To arrange for a free replacement with newly designed constructs, please contact Technical Services at techsupport@origene.com. Please provide your data indicating the transfection efficiency and measurement of gene expression knockdown compared to the scrambled shRNA control (Western Blot data preferred).
*Delivery time may vary from web posted schedule. Occasional delays may occur due to unforeseen complexities in the preparation of your product. International customers may expect an additional 1-2 weeks in shipping.
Customer Reviews 
Loading...